Earlier versions of the Digimet 3000 can be easily upgraded to the current Version 4.0. The unit will need to be sent back to us for conversion.
The Digimet 3000 Version 4.0 allows users to set limits for pulsator ratio parameters, like a high and low value for the B phase of pulsation.
When a user is collecting data with the Digimet 3000 or viewing saved data, the Digimet 3000 display will blink when a parameter value falls outside the desired limits.
This will give guidance to a user as to a potential problem with a pulsator and/or an indication of values that are not appropriate.
NEW FEATURE in the Digimet 3000 Version 4.0
The user will be able to set limits for the following Pulsator Ratio parameters:
* Minimum and Maximum limits can be set for Maximum Vacuum per Pulse; A, B, C & D Phases; and Pulses per Minute.
* A maximum limit can be set for B Fluctuation.
* A minimum limit can be set for Minimum Vacuum per Pulse.
|